0QR30KZ
Replacement Pelvic Bone, Left to No Qualifier with Nonautologous Tissue Substitute, Open Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | Q Lower Bones |
| Operation | R Replacement |
| Body Part | 3 Pelvic Bone, Left |
| Approach | 0 Open |
| Device | K Nonautologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
Procedure Overview
Replacement procedures put in biological or synthetic material that physically takes over the role of all or part of a lower bone. This includes structural bone grafts, cadaver bone allografts, and synthetic bone substitutes used to rebuild a portion of the pelvis, femur, tibia, fibula, or foot bones after tumor resection, severe trauma, or bone loss from infection.
These procedures are performed when a segment of bone is missing or so damaged that it can no longer support the body's structure or function on its own, and simply repairing or repositioning the remaining bone isn't enough. A patient who has had a tumor removed from the femoral shaft, for example, may need the resulting gap filled with a structural allograft to restore the bone's load-bearing capacity.
Anatomy & Axis Detail
Pelvic Bone, Left
On the left side, the pelvic bone unites the ilium, ischium, and pubis into a single ring structure that supports the trunk's weight and transmits it to the lower limb through the hip joint. Replacement here is reserved for situations where a large segment of native bone, often from oncologic resection or catastrophic trauma, must be substituted with a structural implant or allograft to restore pelvic ring integrity, rather than for standard total hip replacement, which is captured under the acetabulum body part. Because pelvic reconstructions of this scale can involve custom 3D-printed implants, operative reports may describe device specifications in detail that go beyond what is needed for body part coding.
Approach: Open
Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.
Device: Nonautologous Tissue Substitute
Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.
Coding & Documentation
Documentation must describe material being put in that takes over the physical role of the bone segment - not material that merely reinforces existing bone, which would be Supplement instead. The type of graft or substitute material and the specific bone segment addressed both need to be clear in the operative note. A frequent error is coding Replacement when bone graft is used to fill a defect but the native bone structure is still largely intact and functional, which points toward Supplement rather than Replacement; another is confusing joint replacement procedures, which are coded to the Lower Joints body system, with bone-segment replacement coded here.