ICD-10-PCS Billable Code

0PR147Z

Replacement Ribs, 1 to 2 to No Qualifier with Autologous Tissue Substitute, Percutaneous Endoscopic Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemP Upper Bones
OperationR Replacement
Body Part1 Ribs, 1 to 2
Approach4 Percutaneous Endoscopic
Device7 Autologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part

Procedure Overview

Replacement procedures in the upper bones involve removing all or part of a bone in the skull, face, thorax, or upper limb and substituting it with a device or biological material that takes over its structural role. Cranioplasty with a synthetic plate after a skull defect, and prosthetic reconstruction of a portion of the humerus or clavicle following tumor removal, are typical examples.

These procedures are performed when a bone is too damaged, diseased, or absent to be repaired or repositioned, and the patient needs a physical substitute to maintain the shape of the skull or the mechanical function of a limb. The material can be a synthetic implant, such as titanium mesh or bone cement, or biological tissue, such as an allograft.

Anatomy & Axis Detail

Ribs, 1 to 2

The first and second ribs form the uppermost, most protected portion of the thoracic cage, sitting close to the subclavian vessels, brachial plexus, and lung apex, which makes surgery in this region technically demanding. Replacement is reported when one or both of these ribs are excised, often due to tumor invasion, deep infection, or thoracic outlet pathology, and the resulting defect is reconstructed with a synthetic device such as mesh, a plate, or a prosthetic strut rather than repositioned native tissue. Because the first two ribs are grouped as a single body part value distinct from lower ribs, procedures on either or both are captured with this code. Reconstruction must account for the confined space and adjacent neurovascular structures to restore chest wall integrity without compromising these structures.

Approach: Percutaneous Endoscopic

Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.

Device: Autologous Tissue Substitute

Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.

Coding & Documentation

Coding from this family requires documentation that a body part was actually taken out and something physically put in its place, not simply reinforced. The device value must match the material used - synthetic versus autologous versus nonautologous tissue - so operative notes describing the graft source matter for accurate code selection. A recurring error is coding replacement when the native bone was left in place and only augmented, which belongs under supplement instead. Coders should also confirm whether the replaced segment is a full bone or only a portion, since this affects the body part value chosen.

Commonly Confused With

SupplementSupplement is the family most often mixed up with replacement: supplement adds material to reinforce an existing structure that remains in place, while replacement requires the original body part to be taken out first.
ResectionResection is also nearby conceptually, since replacement often follows a resection performed in the same operative episode, but resection itself is coded separately and involves no substitute material.