ICD-10-PCS Billable Code

0QRQ0JZ

Replacement Toe Phalanx, Right to No Qualifier with Synthetic Substitute, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemQ Lower Bones
OperationR Replacement
Body PartQ Toe Phalanx, Right
Approach0 Open
DeviceJ Synthetic Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part

Procedure Overview

Replacement procedures put in biological or synthetic material that physically takes over the role of all or part of a lower bone. This includes structural bone grafts, cadaver bone allografts, and synthetic bone substitutes used to rebuild a portion of the pelvis, femur, tibia, fibula, or foot bones after tumor resection, severe trauma, or bone loss from infection.

These procedures are performed when a segment of bone is missing or so damaged that it can no longer support the body's structure or function on its own, and simply repairing or repositioning the remaining bone isn't enough. A patient who has had a tumor removed from the femoral shaft, for example, may need the resulting gap filled with a structural allograft to restore the bone's load-bearing capacity.

Anatomy & Axis Detail

Toe Phalanx, Right

The toe phalanges of the right foot are the small tubular bones forming the digital skeleton distal to the metatarsals, most often the great toe's phalanges given their weight-bearing role at toe-off. Replacement here typically follows severe hallux rigidus, failed prior surgery, or destructive arthritis where joint-preserving options have been exhausted, and involves substituting a resected phalangeal segment or the joint surface with a synthetic implant, silicone spacer, or similar prosthetic material. Because these bones are small and closely applied to surrounding tendons and the plantar plate, precise sizing of the implant matters for maintaining toe length and alignment, and documentation should specify which phalanx (proximal, middle, or distal) and whether a full or partial segment was replaced, since coding depends on the exact bone treated and the device category used.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Synthetic Substitute

Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.

Coding & Documentation

Documentation must describe material being put in that takes over the physical role of the bone segment - not material that merely reinforces existing bone, which would be Supplement instead. The type of graft or substitute material and the specific bone segment addressed both need to be clear in the operative note. A frequent error is coding Replacement when bone graft is used to fill a defect but the native bone structure is still largely intact and functional, which points toward Supplement rather than Replacement; another is confusing joint replacement procedures, which are coded to the Lower Joints body system, with bone-segment replacement coded here.

Commonly Confused With

SupplementSupplement is the closest and most frequently confused root operation, since both can involve grafting material into bone; the distinguishing factor is whether the material takes the place of a missing or resected bone segment (Replacement) or reinforces bone that is still structurally present (Supplement).
InsertionInsertion is distinct because it covers placing a device that doesn't physically substitute for bone tissue, such as a spacer.
RepositionReposition is unrelated in purpose, since it moves existing bone rather than replacing missing bone with new material.