0PRL47Z
Replacement Ulna, Left to No Qualifier with Autologous Tissue Substitute, Percutaneous Endoscopic Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | P Upper Bones |
| Operation | R Replacement |
| Body Part | L Ulna, Left |
| Approach | 4 Percutaneous Endoscopic |
| Device | 7 Autologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
Procedure Overview
Replacement procedures in the upper bones involve removing all or part of a bone in the skull, face, thorax, or upper limb and substituting it with a device or biological material that takes over its structural role. Cranioplasty with a synthetic plate after a skull defect, and prosthetic reconstruction of a portion of the humerus or clavicle following tumor removal, are typical examples.
These procedures are performed when a bone is too damaged, diseased, or absent to be repaired or repositioned, and the patient needs a physical substitute to maintain the shape of the skull or the mechanical function of a limb. The material can be a synthetic implant, such as titanium mesh or bone cement, or biological tissue, such as an allograft.
Anatomy & Axis Detail
Ulna, Left
On the left, the ulna is the medial, more stationary forearm bone whose olecranon and coronoid processes form the hinge of the elbow while its shaft anchors the interosseous membrane connecting it to the radius. Bone replacement here addresses segmental loss from severe fracture, tumor resection, or chronic infection, using structural graft material or a bone substitute to reestablish the ulna's length and the sigmoid notch geometry the radius depends on for smooth rotation. Because the ulna acts as the stable axis around which the radius pivots, any residual angulation after reconstruction can impair both elbow flexion-extension and forearm rotation. Operative documentation should specify the reconstructed ulnar segment clearly, distinguishing it from concurrent elbow joint procedures.
Approach: Percutaneous Endoscopic
Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.
Device: Autologous Tissue Substitute
Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.
Coding & Documentation
Coding from this family requires documentation that a body part was actually taken out and something physically put in its place, not simply reinforced. The device value must match the material used - synthetic versus autologous versus nonautologous tissue - so operative notes describing the graft source matter for accurate code selection. A recurring error is coding replacement when the native bone was left in place and only augmented, which belongs under supplement instead. Coders should also confirm whether the replaced segment is a full bone or only a portion, since this affects the body part value chosen.