0PS234Z
Reposition Ribs, 3 or More to No Qualifier with Internal Fixation Device, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | P Upper Bones |
| Operation | S Reposition |
| Body Part | 2 Ribs, 3 or More |
| Approach | 3 Percutaneous |
| Device | 4 Internal Fixation Device |
| Qualifier | Z No Qualifier |
Operation Definition
Moving to its normal location, or other suitable location, all or a portion of a body part
Procedure Overview
This family describes moving a bone of the skull, face, chest wall, or upper extremity back to its normal anatomic location, or to another location that will function better, without cutting the bone free and removing it from the body. It's the code family used for reducing a displaced fracture, correcting a malunion, or realigning a bone that has shifted out of its normal position due to trauma or a congenital condition.
The procedure preserves the bone's own blood supply and continuity while adjusting its position - fixation with pins, plates, or screws is often part of the same operative episode to hold the corrected alignment in place.
Anatomy & Axis Detail
Ribs, 3 or More
Ribs 3 and beyond make up the bulk of the rib cage that flexes with each breath and provides broad protection to the lungs, and this body part value is used whenever three or more ribs are involved in a single repositioning procedure. Reposition is typically performed for flail chest injuries, where multiple adjacent ribs are fractured and displaced enough to create a paradoxical breathing segment, or for chest wall deformities requiring multi-level correction. Because these ribs act together as a coordinated cage, moving several at once requires attention to maintaining a smooth, symmetric contour across the segment rather than correcting each rib in isolation, and rigid plating is often used to stabilize the repositioned ribs against the ongoing mechanical stress of respiration. The number and level of ribs involved should be documented even though they share this single code.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Internal Fixation Device
Internal fixation device is the general value for hardware such as plates, screws, or rods placed within the body to stabilize bone or joint, used when a more specific configuration is not indicated. It stands in contrast to the named subtypes - Rigid Plate, Intramedullary, Sustained Compression, and Intramedullary Limb Lengthening - which specify how the hardware achieves stabilization.
Coding & Documentation
A coder looks for language describing realignment, reduction, or repositioning of a fragment or whole bone as the defining clue, distinguishing it from repair language about restoring damaged tissue in place. Fixation devices used to hold the new position should be captured through the device value on the same code rather than as a separate procedure when performed at the same operative site. A common error is coding an open reduction and internal fixation entirely as repair, missing that the reduction component is reposition while the fixation is captured through the device character. Another pitfall is failing to distinguish reposition from resection when a bone fragment is removed rather than realigned.