0TV77DZ
Restriction Ureter, Left to No Qualifier with Intraluminal Device, Via Natural or Artificial Opening Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | T Urinary System |
| Operation | V Restriction |
| Body Part | 7 Ureter, Left |
| Approach | 7 Via Natural or Artificial Opening |
| Device | D Intraluminal Device |
| Qualifier | Z No Qualifier |
Operation Definition
Partially closing an orifice or the lumen of a tubular body part
Procedure Overview
Restriction procedures in the urinary system are performed to partially narrow an orifice or the lumen of a tubular structure such as a ureter or the urethra. This family is most commonly encountered in the surgical management of stress urinary incontinence, where a sling, band, or suture technique is used to add resistance at the urethra so that involuntary urine leakage is reduced during coughing, exertion, or sudden movement.
These procedures do not close the passage completely; some degree of flow is preserved, which is what separates restriction from occlusion. Patients typically pursue these options after conservative measures like pelvic floor therapy have not adequately controlled symptoms, or when imaging or urodynamic testing has identified a specific area of the urinary tract that needs mechanical narrowing to function properly.
Anatomy & Axis Detail
Ureter, Left
The left ureter carries urine from the left kidney to the bladder and, like its counterpart, is subject to segmental dilation or vesicoureteral reflux that can lead to recurrent infection or renal deterioration if left uncorrected. Restriction tightens the lumen at the involved level, often with an endoscopic injection, band, or stent-assisted technique, to reduce reflux or redundancy while preserving the conduit's patency rather than closing it off. Its proximity to the sigmoid colon and left iliac vessels along its course makes precise anatomic description of the treated segment important for both surgical planning and record accuracy. Because laterality and level distinguish this procedure from work on the right ureter or on the kidney pelvis, documentation should state clearly that the left ureter, and not an adjacent structure, was the target of the narrowing.
Approach: Via Natural or Artificial Opening
Via Natural or Artificial Opening means the instrument reaches the target site by passing through an existing body orifice, such as the mouth or urethra, or a surgically created opening like a stoma, without additional incision or scope guidance. It is distinguished from the Endoscopic variant by the absence of a visualizing scope, and from External by actually traversing into the body through that opening.
Device: Intraluminal Device
Intraluminal Device denotes a single device, such as a stent or occlusion device, positioned within the lumen of a tubular body part like a vessel, duct, or airway to maintain patency or occlude flow. It carries no drug coating or radioactivity, distinguishing it from the drug-eluting, radioactive, and bioactive intraluminal device values, and from Extraluminal Device, which sits outside rather than inside the lumen.
Coding & Documentation
Coders should verify that the documentation describes a partial narrowing of the passage, such as placement of a sling or band, or plication of tissue around the urethra or ureter, without complete closure. The device or material used, along with the specific urinary structure treated, must be clearly stated in the operative report to support code assignment. A common error is mistaking Restriction for Occlusion, which is used only when the lumen is completely closed off, or for Supplement when the intent is reinforcement of a wall rather than narrowing of the passage itself.
Documentation should also clarify whether a device remains in place, since that affects whether a device value is reported alongside the procedure.