0PW93JZ
Revision Clavicle, Right to No Qualifier with Synthetic Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | P Upper Bones |
| Operation | W Revision |
| Body Part | 9 Clavicle, Right |
| Approach | 3 Percutaneous |
| Device | J Synthetic Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
This family covers procedures that correct a problem with hardware already implanted in one of the upper bones - the skull, facial bones, sternum, ribs, or the cervical and thoracic vertebrae, scapula, clavicle, or humerus. A patient who had a plate, screw, rod, or other fixation device placed after a fracture or spinal surgery may develop a loose screw, a bent plate, or hardware that has shifted out of its intended position. Revision procedures adjust, tighten, reposition, or partially rebuild that existing device rather than removing it and starting over.
Surgeons turn to these procedures when imaging or symptoms - pain, instability, a visible or palpable lump, or a healing fracture that isn't aligning properly - point to a hardware problem rather than a new injury. The goal is to restore the device to proper function or position using the smallest intervention that will do the job, which often means less recovery time than a full hardware exchange.
Anatomy & Axis Detail
Clavicle, Right
Revision of the right clavicle addresses hardware previously implanted along this long, S-shaped bone that connects the sternum to the shoulder, commonly plates and screws used to fix a clavicle fracture or hardware from a distal clavicle or acromioclavicular joint reconstruction. The clavicle's subcutaneous position and constant motion with shoulder shrugging and arm elevation predispose fixation hardware to prominence, irritation, or loosening, which frequently prompts revision rather than complete removal. Because the bone lies directly over the subclavian vessels and brachial plexus, any adjustment of embedded hardware requires careful surgical planning. Coding requires confirming that the intervention corrects or repositions an existing device in place, with right laterality specified, rather than representing a full hardware exchange coded elsewhere.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Synthetic Substitute
Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.
Coding & Documentation
A coder should look for documentation that names the specific device involved (plate, screw, rod, wire, external fixator component) and describes what was done to it - repositioned, tightened, partially replaced, or otherwise corrected - rather than fully removed and swapped. Operative notes should specify the exact upper bone treated, since the qualifier and body part values differ by site.
The most common assignment error is confusing Revision with Removal followed by Insertion when the surgeon actually took the whole device out and put in a brand-new one; that scenario is coded as separate root operations, not Revision. Another frequent slip is coding Revision when the note describes a routine Change of an identical device without any correction of malfunction or malposition - that belongs under Change instead.