ICD-10-PCS Billable Code

0UW80DZ

Revision Fallopian Tube to No Qualifier with Intraluminal Device, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemU Female Reproductive System
OperationW Revision
Body Part8 Fallopian Tube
Approach0 Open
DeviceD Intraluminal Device
QualifierZ No Qualifier

Operation Definition

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Procedure Overview

This family covers procedures to fix or reposition a device that was previously implanted in the female reproductive tract, most often a vaginal pessary that has shifted, an intrauterine device that has migrated, or a mechanical component of an artificial sphincter or slings used for pelvic organ support. Revision does not replace the entire device with a new one; instead, the surgeon adjusts, repositions, or repairs the malfunctioning part while leaving as much of the original device in place as possible.

Patients typically need this procedure because a device is causing pain, has moved out of proper position, is no longer controlling symptoms such as incontinence or prolapse, or has developed a mechanical problem like a frayed mesh or displaced anchor. The goal is to restore the device to proper function without the larger recovery associated with full removal and reimplantation.

Because pelvic anatomy is compact and devices are often placed near the bladder, urethra, or bowel, revision procedures require careful surgical planning to avoid injury to nearby structures while correcting the original device's position or function.

Anatomy & Axis Detail

Fallopian Tube

Revision of the fallopian tube involves correcting or adjusting a device or the outcome of a prior procedure on the tube, such as repositioning tubal clips or rings placed for sterilization, addressing a malfunctioning fixation used in tuboplasty, or correcting a complication from earlier reconstructive surgery. The tube's narrow, delicate lumen makes it particularly vulnerable to further injury during revision, and surgeons must balance correcting the identified problem against the risk of causing additional scarring that could impair future patency or fertility. This root operation is distinct from simply repeating a reconstructive procedure, since Revision specifically targets an existing device or a prior procedure's malfunctioning or displaced result rather than treating new pathology, and documentation should identify what was originally placed and what specifically required correction.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Intraluminal Device

Intraluminal Device denotes a single device, such as a stent or occlusion device, positioned within the lumen of a tubular body part like a vessel, duct, or airway to maintain patency or occlude flow. It carries no drug coating or radioactivity, distinguishing it from the drug-eluting, radioactive, and bioactive intraluminal device values, and from Extraluminal Device, which sits outside rather than inside the lumen.

Coding & Documentation

A coder assigns from this family when the operative note describes correcting, repositioning, or repairing part of an existing device rather than removing it outright. Supporting documentation should specify which device is involved (pessary, sling, IUD, artificial sphincter component), what was wrong with it, and exactly what corrective maneuver was performed, such as retensioning a sling or repositioning a shifted mesh anchor.

The most common assignment error is confusing Revision with Removal followed by a new Insertion when the surgeon actually took out the entire device and put in a brand new one; that scenario is coded as two separate root operations, not a single Revision. Another frequent mistake is coding Revision when the note only describes adjusting fit or tension of a device still functioning normally, which may not meet the threshold of correcting a malfunction and instead falls under Inspection or a different qualifier.

Commonly Confused With

RemovalRemoval is often confused with Revision, but Removal takes the device out entirely with no correction performed on remaining components, while Revision leaves the device in place and fixes only the problematic portion.
SupplementSupplement can be mistaken for Revision when reinforcing material is added to an existing repair; Supplement adds bulking or reinforcing material without correcting a malfunction, whereas Revision specifically addresses a device that is broken or displaced.