0PWV0JZ
Revision Finger Phalanx, Left to No Qualifier with Synthetic Substitute, Open Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | P Upper Bones |
| Operation | W Revision |
| Body Part | V Finger Phalanx, Left |
| Approach | 0 Open |
| Device | J Synthetic Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
This family covers procedures that correct a problem with hardware already implanted in one of the upper bones - the skull, facial bones, sternum, ribs, or the cervical and thoracic vertebrae, scapula, clavicle, or humerus. A patient who had a plate, screw, rod, or other fixation device placed after a fracture or spinal surgery may develop a loose screw, a bent plate, or hardware that has shifted out of its intended position. Revision procedures adjust, tighten, reposition, or partially rebuild that existing device rather than removing it and starting over.
Surgeons turn to these procedures when imaging or symptoms - pain, instability, a visible or palpable lump, or a healing fracture that isn't aligning properly - point to a hardware problem rather than a new injury. The goal is to restore the device to proper function or position using the smallest intervention that will do the job, which often means less recovery time than a full hardware exchange.
Anatomy & Axis Detail
Finger Phalanx, Left
The left finger phalanges - proximal, middle, and distal, spanning the index through little fingers - are narrow bones whose alignment directly determines a digit's ability to flex, extend, and participate in coordinated grip. Revision in this region typically corrects hardware complications following a prior fracture fixation, such as a pin, screw, or plate placed across a shaft or condylar fracture that has failed to maintain reduction or has caused adjacent tendon irritation. Because the extensor and flexor tendons run in close proximity to these bones, hardware that becomes prominent or malpositioned can produce triggering, adhesion, or loss of digit motion, making timely revision important for restoring hand function. A previously implanted interphalangeal joint prosthesis may also be revised at this site. As with the right hand, the specific digit and phalangeal segment should be documented given the number of similar bones involved.
Approach: Open
Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.
Device: Synthetic Substitute
Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.
Coding & Documentation
A coder should look for documentation that names the specific device involved (plate, screw, rod, wire, external fixator component) and describes what was done to it - repositioned, tightened, partially replaced, or otherwise corrected - rather than fully removed and swapped. Operative notes should specify the exact upper bone treated, since the qualifier and body part values differ by site.
The most common assignment error is confusing Revision with Removal followed by Insertion when the surgeon actually took the whole device out and put in a brand-new one; that scenario is coded as separate root operations, not Revision. Another frequent slip is coding Revision when the note describes a routine Change of an identical device without any correction of malfunction or malposition - that belongs under Change instead.