0PWC07Z
Revision Humeral Head, Right to No Qualifier with Autologous Tissue Substitute, Open Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | P Upper Bones |
| Operation | W Revision |
| Body Part | C Humeral Head, Right |
| Approach | 0 Open |
| Device | 7 Autologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
This family covers procedures that correct a problem with hardware already implanted in one of the upper bones - the skull, facial bones, sternum, ribs, or the cervical and thoracic vertebrae, scapula, clavicle, or humerus. A patient who had a plate, screw, rod, or other fixation device placed after a fracture or spinal surgery may develop a loose screw, a bent plate, or hardware that has shifted out of its intended position. Revision procedures adjust, tighten, reposition, or partially rebuild that existing device rather than removing it and starting over.
Surgeons turn to these procedures when imaging or symptoms - pain, instability, a visible or palpable lump, or a healing fracture that isn't aligning properly - point to a hardware problem rather than a new injury. The goal is to restore the device to proper function or position using the smallest intervention that will do the job, which often means less recovery time than a full hardware exchange.
Anatomy & Axis Detail
Humeral Head, Right
Revision of the right humeral head pertains to correcting a component or fixation device at the proximal, ball-shaped end of the right humerus that articulates with the glenoid, most often the humeral component of a shoulder arthroplasty or hardware stabilizing a proximal humerus fracture. This region bears substantial rotational stress during shoulder movement, so loosening of a stemmed component, malalignment, or wear at the head-neck junction is a frequent reason for reoperation. Because the humeral head is coded separately from the humeral shaft, the operative note must clearly indicate that the proximal component, rather than shaft hardware, was the target of correction. Right laterality should be confirmed, and the procedure should reflect adjustment or partial exchange rather than complete implant removal and reinsertion.
Approach: Open
Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.
Device: Autologous Tissue Substitute
Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.
Coding & Documentation
A coder should look for documentation that names the specific device involved (plate, screw, rod, wire, external fixator component) and describes what was done to it - repositioned, tightened, partially replaced, or otherwise corrected - rather than fully removed and swapped. Operative notes should specify the exact upper bone treated, since the qualifier and body part values differ by site.
The most common assignment error is confusing Revision with Removal followed by Insertion when the surgeon actually took the whole device out and put in a brand-new one; that scenario is coded as separate root operations, not Revision. Another frequent slip is coding Revision when the note describes a routine Change of an identical device without any correction of malfunction or malposition - that belongs under Change instead.
