0QWC3JZ
Revision Lower Femur, Left to No Qualifier with Synthetic Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | Q Lower Bones |
| Operation | W Revision |
| Body Part | C Lower Femur, Left |
| Approach | 3 Percutaneous |
| Device | J Synthetic Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
Revision procedures address a device that was previously implanted in a lower bone - such as a rod, plate, screw, or bone cement construct - when it has shifted position, is malfunctioning, or is otherwise not working as intended. The bone itself is not the primary target; the hardware or material within or against it is.
These procedures are common after orthopedic fixation surgery when follow-up imaging or symptoms reveal that a fixation device has loosened, backed out, broken, or migrated. Surgeons go back in to reposition, tighten, repair, or otherwise correct the existing device to the extent possible, aiming to avoid a full device replacement if the original hardware can still function once adjusted.
Anatomy & Axis Detail
Lower Femur, Left
The left lower femur, the distal end of the thighbone forming part of the knee joint, often bears plates and screws for supracondylar fracture fixation or the femoral component of a knee replacement. Revision is performed when this hardware loosens, migrates, or malfunctions, a concern heightened by the proximity of the knee joint, where even minor hardware displacement can affect alignment, range of motion, or contact with the tibial component in a prosthetic joint. The distal femur's broad cancellous bone near the condyles can also lose fixation strength over time under repetitive knee-bending loads, prompting correction of screws or plates before failure worsens. This code applies to adjusting the existing device already placed in the left lower femur, separate from new implantation or complete removal.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Synthetic Substitute
Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.
Coding & Documentation
The documentation needs to describe correction of a device already in place - repositioning a displaced screw, replacing a broken segment of a rod, or repairing a malfunctioning fixation component - rather than removal of the device followed by insertion of a brand-new one. If the surgeon fully swaps out the device rather than fixing the one already present, Removal plus Insertion or Replacement is usually the more accurate combination.
A frequent assignment mistake is coding Revision for a straightforward hardware removal with no correction performed, or for a first-time hardware placement. Coders should also verify the correct body part value reflects the bone where the device sits, since Revision codes are structured around device location rather than the device type itself.
