0QWB37Z
Revision Lower Femur, Right to No Qualifier with Autologous Tissue Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | Q Lower Bones |
| Operation | W Revision |
| Body Part | B Lower Femur, Right |
| Approach | 3 Percutaneous |
| Device | 7 Autologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
Revision procedures address a device that was previously implanted in a lower bone - such as a rod, plate, screw, or bone cement construct - when it has shifted position, is malfunctioning, or is otherwise not working as intended. The bone itself is not the primary target; the hardware or material within or against it is.
These procedures are common after orthopedic fixation surgery when follow-up imaging or symptoms reveal that a fixation device has loosened, backed out, broken, or migrated. Surgeons go back in to reposition, tighten, repair, or otherwise correct the existing device to the extent possible, aiming to avoid a full device replacement if the original hardware can still function once adjusted.
Anatomy & Axis Detail
Lower Femur, Right
The right lower femur, encompassing the distal metaphysis and condyles just above the knee, is frequently instrumented with plates, screws, or intramedullary nails after supracondylar or intercondylar fractures, or with the femoral component of a total knee prosthesis. Revision addresses hardware loosening, screw backout near the articular surface, or plate failure, complications of particular concern here because the distal femur sits close to the knee joint, where malpositioned hardware can directly impair joint mechanics or cause soft-tissue irritation. This region's dense trabecular bone near the joint line also makes secure purchase more challenging than in the shaft, contributing to a higher likelihood of fixation problems requiring correction. The code reflects repositioning or repairing an existing device in the right lower femur, not its initial insertion or full removal.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Autologous Tissue Substitute
Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.
Coding & Documentation
The documentation needs to describe correction of a device already in place - repositioning a displaced screw, replacing a broken segment of a rod, or repairing a malfunctioning fixation component - rather than removal of the device followed by insertion of a brand-new one. If the surgeon fully swaps out the device rather than fixing the one already present, Removal plus Insertion or Replacement is usually the more accurate combination.
A frequent assignment mistake is coding Revision for a straightforward hardware removal with no correction performed, or for a first-time hardware placement. Coders should also verify the correct body part value reflects the bone where the device sits, since Revision codes are structured around device location rather than the device type itself.