0QWF3KZ
Revision Patella, Left to No Qualifier with Nonautologous Tissue Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | Q Lower Bones |
| Operation | W Revision |
| Body Part | F Patella, Left |
| Approach | 3 Percutaneous |
| Device | K Nonautologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
Revision procedures address a device that was previously implanted in a lower bone - such as a rod, plate, screw, or bone cement construct - when it has shifted position, is malfunctioning, or is otherwise not working as intended. The bone itself is not the primary target; the hardware or material within or against it is.
These procedures are common after orthopedic fixation surgery when follow-up imaging or symptoms reveal that a fixation device has loosened, backed out, broken, or migrated. Surgeons go back in to reposition, tighten, repair, or otherwise correct the existing device to the extent possible, aiming to avoid a full device replacement if the original hardware can still function once adjusted.
Anatomy & Axis Detail
Patella, Left
The left patella, the sesamoid bone within the quadriceps tendon that articulates with the femoral trochlea during knee flexion and extension, may be stabilized with tension band wiring or screws following a fracture that disrupts the extensor mechanism. Revision is undertaken when this fixation loosens, wires migrate, or a screw backs out toward the overlying skin, issues made more noticeable by the patella's thin soft-tissue envelope and its constant motion against the femur with every knee movement. Correcting malpositioned hardware here aims to preserve smooth patellofemoral tracking and full active knee extension. This code describes adjustment or repair of the device already present in the left patella, not a new fixation procedure or its outright removal.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Nonautologous Tissue Substitute
Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.
Coding & Documentation
The documentation needs to describe correction of a device already in place - repositioning a displaced screw, replacing a broken segment of a rod, or repairing a malfunctioning fixation component - rather than removal of the device followed by insertion of a brand-new one. If the surgeon fully swaps out the device rather than fixing the one already present, Removal plus Insertion or Replacement is usually the more accurate combination.
A frequent assignment mistake is coding Revision for a straightforward hardware removal with no correction performed, or for a first-time hardware placement. Coders should also verify the correct body part value reflects the bone where the device sits, since Revision codes are structured around device location rather than the device type itself.