0RWE38Z
Revision Sternoclavicular Joint, Right to No Qualifier with Spacer, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | R Upper Joints |
| Operation | W Revision |
| Body Part | E Sternoclavicular Joint, Right |
| Approach | 3 Percutaneous |
| Device | 8 Spacer |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
Revision procedures address a previously placed device in an upper joint, correcting a malfunction or fixing the position of a device that has shifted out of place. This applies to hardware such as joint prostheses, fixation plates, screws, or anchors that were implanted in an earlier surgery and are now causing problems, whether through loosening, wear, mechanical failure, or migration away from their intended location. The surgeon works to fix the existing device to the extent possible rather than necessarily removing and replacing the entire construct.
Patients need this type of procedure when a prior joint surgery, such as a shoulder or elbow reconstruction using anchors or hardware, develops complications months or years later. Symptoms prompting evaluation often include new pain, instability, clicking, or imaging findings showing hardware displacement or breakage. The goal of revision is to restore the device's intended function and relieve the symptoms it was causing without necessarily performing a full replacement operation.
Anatomy & Axis Detail
Sternoclavicular Joint, Right
The right sternoclavicular joint links the medial clavicle to the manubrium and first costal cartilage, serving as the sole bony connection between the upper limb and axial skeleton on that side. Revision procedures here most often correct problems following prior reconstruction for instability, degenerative arthritis, or post-traumatic malalignment, including graft failure, hardware migration, or persistent subluxation. Because the joint lies immediately anterior to the great vessels, trachea, and mediastinum, any revision demands meticulous attention to posterior displacement risk and often involves tendon graft repositioning rather than metal hardware, given the joint's limited space and mobility requirements. Surgeons document whether correction addresses malposition, protruding graft material, or nonfunctioning stabilization without full component exchange, which determines whether revision, rather than removal or replacement, is the accurate root operation to report.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Spacer
In Medical and Surgical procedures, a Spacer is a temporary, non-articulating device left in a joint or space after a component is removed, most often an antibiotic-impregnated cement block placed during a staged joint revision to control infection while preserving space and alignment. It is not intended to move like a real joint. It differs from an Articulating Spacer, which is shaped to permit some motion during the interim period, and from a permanent Synthetic Substitute.
Coding & Documentation
A Revision code is used when the documentation specifically describes correcting, adjusting, or repositioning a device that was already present in the joint, rather than removing a device and inserting a brand-new one, which would instead be coded as Removal followed by Insertion or captured under Replacement if the device itself is a joint substitute. Coders should look for terms like loosening, malposition, hardware failure, or device malfunction tied to an existing implant. A common assignment error is defaulting to Revision any time a patient returns to the operating room after a prior joint procedure, even when the surgeon actually removes the old device entirely and inserts a completely new one; in that scenario, separate Removal and Insertion or Replacement codes are more accurate. Coders should also confirm which specific joint and device are being revised, since multiple components may be addressed differently within the same operative session.