0SWHX8Z
Revision Tarsal Joint, Right to No Qualifier with Spacer, External Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | S Lower Joints |
| Operation | W Revision |
| Body Part | H Tarsal Joint, Right |
| Approach | X External |
| Device | 8 Spacer |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
Revision procedures correct a malfunctioning device already implanted in a lower joint, or reposition a device that has shifted out of place, without necessarily removing and replacing the whole implant. Examples include tightening a loosened hip component, adjusting a worn knee liner, or repositioning a dislocated joint implant back into alignment. The reason for surgery is a problem with hardware from an earlier operation rather than new injury to native tissue.
These procedures are often needed years after an initial joint replacement, as components can loosen, wear, or shift with normal use. Surgeons aim to fix the specific mechanical problem while preserving as much of the existing implant and surrounding bone as possible, since more extensive revisions carry greater surgical risk and longer recovery.
Anatomy & Axis Detail
Tarsal Joint, Right
Revision at a tarsal joint on the right side pertains to the cluster of articulations among the calcaneus, talus, navicular, and cuboid, an area sometimes fused or reconstructed to manage severe flatfoot deformity, arthritis, or post-traumatic instability. When hardware such as screws, plates, or a fusion cage placed at one of these joints backs out, breaks, or fails to achieve solid union, revision restores proper alignment of the hindfoot and midfoot and may involve removing broken fixation, correcting positioning, or replacing components. Given the complexity and number of individual articulations within the tarsal region, precise identification of which joint underwent the original procedure is important, and documentation should clarify whether the revision addresses malposition, mechanical complication, or displacement of previously implanted material.
Approach: External
External approach applies to procedures performed directly on the skin or mucous membrane, or on an accessible body surface, without any instrumentation passing through a puncture or orifice. It covers things like manual reduction of a fracture or excision of a skin lesion. It differs from Via Natural or Artificial Opening in that no internal passage is entered at all, only the exposed surface.
Device: Spacer
In Medical and Surgical procedures, a Spacer is a temporary, non-articulating device left in a joint or space after a component is removed, most often an antibiotic-impregnated cement block placed during a staged joint revision to control infection while preserving space and alignment. It is not intended to move like a real joint. It differs from an Articulating Spacer, which is shaped to permit some motion during the interim period, and from a permanent Synthetic Substitute.
Coding & Documentation
Documentation needs to identify that an existing device was the target of correction, whether through repositioning, adjustment, or partial component exchange, and that the fix did not amount to a full swap of the entire prosthesis. Notes describing loosening, malposition, or component wear typically support Revision. A common error arises when a full component exchange occurs during a documented revision surgery; if the entire device is replaced, the correct root operation is Replacement, even though the surgeon may call it revision arthroplasty.