0SWK34Z
Revision Tarsometatarsal Joint, Right to No Qualifier with Internal Fixation Device, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | S Lower Joints |
| Operation | W Revision |
| Body Part | K Tarsometatarsal Joint, Right |
| Approach | 3 Percutaneous |
| Device | 4 Internal Fixation Device |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
Revision procedures correct a malfunctioning device already implanted in a lower joint, or reposition a device that has shifted out of place, without necessarily removing and replacing the whole implant. Examples include tightening a loosened hip component, adjusting a worn knee liner, or repositioning a dislocated joint implant back into alignment. The reason for surgery is a problem with hardware from an earlier operation rather than new injury to native tissue.
These procedures are often needed years after an initial joint replacement, as components can loosen, wear, or shift with normal use. Surgeons aim to fix the specific mechanical problem while preserving as much of the existing implant and surrounding bone as possible, since more extensive revisions carry greater surgical risk and longer recovery.
Anatomy & Axis Detail
Tarsometatarsal Joint, Right
Revision at the right tarsometatarsal joint, the Lisfranc articulation connecting the midfoot to the metatarsal bases, typically addresses complications following prior fusion or fixation performed for post-traumatic arthritis or Lisfranc injury instability. Hardware in this region, such as screws or plates spanning the tarsometatarsal complex, can loosen, break, or fail to achieve bony union given the significant shear forces transmitted across the midfoot during gait, and revision may involve removing broken implants, correcting malalignment, or replacing components to restore a stable arch. Because nonunion at this site can be particularly disabling for weight-bearing, documentation should specify whether the procedure corrects device position, exchanges hardware, or removes material without replacing it.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Internal Fixation Device
Internal fixation device is the general value for hardware such as plates, screws, or rods placed within the body to stabilize bone or joint, used when a more specific configuration is not indicated. It stands in contrast to the named subtypes - Rigid Plate, Intramedullary, Sustained Compression, and Intramedullary Limb Lengthening - which specify how the hardware achieves stabilization.
Coding & Documentation
Documentation needs to identify that an existing device was the target of correction, whether through repositioning, adjustment, or partial component exchange, and that the fix did not amount to a full swap of the entire prosthesis. Notes describing loosening, malposition, or component wear typically support Revision. A common error arises when a full component exchange occurs during a documented revision surgery; if the entire device is replaced, the correct root operation is Replacement, even though the surgeon may call it revision arthroplasty.