ICD-10-PCS Billable Code

02UF3KJ

Supplement Aortic Valve to Truncal Valve with Nonautologous Tissue Substitute, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System2 Heart and Great Vessels
OperationU Supplement
Body PartF Aortic Valve
Approach3 Percutaneous
DeviceK Nonautologous Tissue Substitute
QualifierJ Truncal Valve

Operation Definition

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

Procedure Overview

Supplement procedures add biological or synthetic material to reinforce or enhance a portion of the heart or a great vessel without removing the existing structure. Common examples include patch repair of a septal defect, reinforcing a weakened area of the aortic wall, or placing material to strengthen a valve annulus during repair.

The goal is to shore up tissue that is present but insufficient on its own, whether because of a congenital hole, an aneurysm that has thinned the vessel wall, or a valve structure that needs extra support to function properly. Unlike a replacement, the body's own tissue stays in place and the added material works alongside it.

Patients typically encounter this term in the context of congenital defect closures, aortic aneurysm repairs, and valve repair techniques that use patches, rings, or other reinforcing materials rather than swapping out the whole valve or vessel.

Anatomy & Axis Detail

Aortic Valve

The aortic valve is the three-leaflet structure separating the left ventricle from the aorta, opening during systole to allow forward ejection of blood and closing in diastole to prevent regurgitation; its leaflets can become calcified, myxomatous, or perforated from endocarditis. Supplementing the aortic valve involves augmenting a leaflet or the annulus with a patch of pericardial tissue or synthetic material to restore adequate coaptation and leaflet surface area, a technique often used in aortic valve repair for cusp perforation or prolapse as an alternative to replacement, particularly in younger patients where preserving the native valve avoids the risks of prosthetic valves and anticoagulation. Because leaflet geometry is precise, even small discrepancies in patch sizing can cause stenosis or recurrent regurgitation, so surgeons frequently use intraoperative echocardiography to assess the repair before closing.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Nonautologous Tissue Substitute

Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.

Qualifier: Truncal Valve

This qualifier identifies the truncal valve, the single valve serving a persistent truncus arteriosus, as the object of a valve procedure. It is distinguished from separate aortic and pulmonary valve qualifiers, which apply only once the great vessels and their valves have been surgically separated into two distinct outflows.

Coding & Documentation

Coders assign Supplement when the note documents that material, biological or synthetic, was added to reinforce or augment existing anatomy, such as closing a septal defect with a patch or buttressing a vessel wall. The documentation should identify the material used and confirm that native tissue was not removed and replaced, only strengthened.

The most frequent error is confusing patch closure of a defect, which is Supplement, with actual replacement of a structure, which requires taking out the original part. Another common mistake is missing that some valve repairs combine Supplement for annuloplasty ring placement with Repair for other steps done in the same operative session, each of which needs its own code.

Commonly Confused With

ReplacementSupplement is closely confused with Replacement, where the distinction is whether native tissue is removed, as in Replacement, or left in place and reinforced, as in Supplement.
RepairIt also overlaps with Repair, the default root operation used when no other term fits; if a patch is placed specifically to reinforce or close a defect using added material, Supplement takes priority over Repair.
RestrictionCoders should also distinguish Supplement from Restriction, since a patch that narrows an oversized structure to normal caliber may actually reflect a Restriction if that narrowing is the primary intent rather than reinforcement.