0PU937Z
Supplement Clavicle, Right to No Qualifier with Autologous Tissue Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | P Upper Bones |
| Operation | U Supplement |
| Body Part | 9 Clavicle, Right |
| Approach | 3 Percutaneous |
| Device | 7 Autologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
Procedure Overview
Supplement procedures add biological or synthetic material to reinforce or augment a bone of the skull, face, thorax, or upper limb that remains anatomically in place, rather than replacing or repairing damaged tissue. Common examples include bone grafting to reinforce a weakened area of the skull, or augmenting a thin area of the sternum or scapula with mesh or cement to add structural strength.
This approach is chosen when the native bone is largely intact and functional but needs extra support, often to prevent future fracture, to build up bone stock before another procedure, or to strengthen a surgical repair site.
Anatomy & Axis Detail
Clavicle, Right
The right clavicle is a subcutaneous, S-shaped bone linking the sternum to the shoulder, and its superficial position makes it prone to fracture as well as nonunion when healing fails. Supplement procedures here generally address nonunion or bone loss, using graft material to bridge a gap and restore the strut-like function the clavicle serves in holding the shoulder girdle away from the chest wall. Because the bone lies just beneath the skin with limited soft tissue coverage, graft incorporation and wound healing are closely tied to how well the reconstruction is protected postoperatively. Documentation should note the right-sided laterality and whether the graft is autologous or a synthetic substitute, since this affects expected healing time.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Autologous Tissue Substitute
Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.
Coding & Documentation
Coders should confirm the operative note describes material being added to reinforce a structure that stays in place, not material substituting for a removed part. The device or graft type documented determines the correct device value - autograft, allograft, synthetic substitute, or nonautologous tissue - so vague documentation of "bone graft" without a source can complicate accurate coding. A common mistake is coding supplement when the surgeon actually performed a replacement, particularly in cranioplasty cases where it's unclear whether native bone was removed first. Another frequent error is missing a supplement code entirely when a graft was placed during a repair or reposition procedure, since it may require a separate code rather than being bundled in.