ICD-10-PCS Billable Code

04UL3JZ

Supplement Femoral Artery, Left to No Qualifier with Synthetic Substitute, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System4 Lower Arteries
OperationU Supplement
Body PartL Femoral Artery, Left
Approach3 Percutaneous
DeviceJ Synthetic Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

Procedure Overview

Supplement procedures reinforce or augment an artery using additional biological or synthetic material without removing the native vessel segment, distinguishing them from Replacement, where the diseased tissue is excised. In the lower arteries this typically takes the form of patch angioplasty at an endarterectomy site, or endovascular placement of a covered stent graft that lines and reinforces a weakened or aneurysmal segment while the native artery remains in place.

Patients undergo this type of procedure when an artery has been narrowed by plaque removal and needs a widening patch to prevent restenosis, or when an aneurysm needs endoluminal reinforcement rather than open resection. It is common in both open vascular surgery and increasingly in endovascular aneurysm repair, where covered stent grafts are deployed to reinforce the arterial wall from within.

Anatomy & Axis Detail

Femoral Artery, Left

The left femoral artery supplies the left lower extremity, traversing the femoral triangle and giving off the profunda femoris before continuing as the superficial femoral artery toward the thigh and leg. Supplement procedures here reinforce a weakened arterial wall segment, commonly at a site of aneurysmal degeneration, pseudoaneurysm, or a prior endarterectomy or angioplasty scar, using patch angioplasty material to broaden the lumen and restore wall strength. This vessel's superficial location makes it accessible for open repair, and because it is also a frequent catheterization access site, supplementation is often performed to correct access-related injury alongside management of atherosclerotic narrowing that threatens limb perfusion.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Synthetic Substitute

Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.

Coding & Documentation

Coders should confirm from the operative note that the native artery segment was left in place and that material, whether a bovine pericardial patch, synthetic patch, or covered endograft, was added to reinforce or widen it. The device value must reflect the specific material used, and the body part value should reflect the arterial segment being reinforced, which for endovascular aneurysm repair can span multiple named segments requiring multiple codes.

A frequent error is coding patch angioplasty performed after an endarterectomy as part of the Extirpation code for the plaque removal rather than as a separate Supplement code, when current guidance requires both steps to be captured. Another common mistake is applying Replacement device values to what is actually a reinforcing supplement.

Commonly Confused With

ReplacementReplacement is the primary point of confusion, since both use graft material, but the deciding factor is whether the native vessel was excised, which points to Replacement, or left intact and reinforced, which points to Supplement.
RestrictionEndovascular aneurysm repair in particular can be miscoded as Restriction if the coder focuses only on the narrowing effect of the graft rather than recognizing that new device material was permanently placed to reinforce the wall, which is the hallmark of Supplement.