ICD-10-PCS Billable Code

0YUE07Z

Supplement Femoral Region, Bilateral to No Qualifier with Autologous Tissue Substitute, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemY Anatomical Regions, Lower Extremities
OperationU Supplement
Body PartE Femoral Region, Bilateral
Approach0 Open
Device7 Autologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

Procedure Overview

Supplement procedures in this family involve placing biological or synthetic material into or onto a lower extremity anatomical region to physically reinforce or add bulk to existing tissue, rather than to replace missing structure. Surgical mesh used to reinforce weakened fascia or a defect in the leg or foot region, or an autologous or donor graft layered onto tissue to strengthen it, are typical examples.

This type of procedure is chosen when the body part is present and largely intact but needs additional support to hold its shape, resist strain, or heal properly, such as reinforcing a soft-tissue closure after trauma or a prior surgical repair. It differs from simply closing or repairing a wound because material is deliberately added to bolster the area beyond what the patient's own tissue can currently provide.

Anatomy & Axis Detail

Femoral Region, Bilateral

Bilateral femoral region supplementation reinforces the groin-to-proximal-thigh tissue on both sides in a single operative episode, typically performed for bilateral femoral hernia repair or combined reconstruction after bilateral vascular access site complications. Each femoral region contains the femoral triangle with its neurovascular contents, so mesh or graft placement on both sides demands symmetric attention to avoid compressing the femoral vessels or nerve while achieving durable fascial reinforcement. Choosing this bilateral body part value requires that the same root operation be performed on corresponding structures on both sides during the same procedure; asymmetric findings or staged bilateral repair would instead be coded with laterality-specific values. The combined bilateral approach reduces the number of anesthetic exposures for patients with symmetric femoral pathology.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Autologous Tissue Substitute

Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.

Coding & Documentation

A coder assigns Supplement when documentation shows material was added to reinforce or augment a body part that remains present, with the graft or mesh serving a support function rather than substituting for an absent structure. The note should specify the material used, whether autograft, allograft, or synthetic mesh, since device and substance qualifiers affect code selection. A common error is coding Supplement when the material is actually replacing a resected or absent structure, which belongs to Replacement instead, or coding Repair when reinforcing material was in fact placed, which should be captured as Supplement.

Commonly Confused With

ReplacementSupplement is most often confused with Replacement, but Replacement substitutes for a body part that is absent or has been taken out, while Supplement reinforces a body part that remains in place.
RepairIt is also distinguished from Repair, since Repair restores tissue using the patient's own structure without adding reinforcing material.
InsertionInsertion is a related but separate concept, used when a device is placed to monitor, assist, or perform a function rather than to physically reinforce tissue.