0SU93JZ
Supplement Hip Joint, Right to No Qualifier with Synthetic Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | S Lower Joints |
| Operation | U Supplement |
| Body Part | 9 Hip Joint, Right |
| Approach | 3 Percutaneous |
| Device | J Synthetic Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
Procedure Overview
Supplement procedures add biological or synthetic material to reinforce or augment a lower joint that is still structurally present but needs additional support. Ligament reconstruction, such as an ACL or PCL graft in the knee, is the classic example, along with labral augmentation in the hip or cartilage grafting. Unlike replacement, the native joint stays in place; the surgery strengthens a weakened or torn portion of it.
Grafts can come from the patient's own tissue, a donor, or synthetic material, and the choice often depends on age, activity level, and the structure being reinforced. These procedures are common after athletic injuries, aiming to restore stability so the joint can withstand normal or athletic loads again.
Anatomy & Axis Detail
Hip Joint, Right
The right hip joint is the ball-and-socket articulation where the femoral head meets the acetabulum of the pelvis, one of the body's largest weight-bearing joints. Supplement procedures at this joint involve placing material, such as bone graft to fill a defect, or a synthetic liner or spacer, to reinforce existing joint structures without removing and replacing the femoral head or acetabular surface as a whole, which would instead be coded as replacement. This approach is used for localized cartilage or bone stock deficiency, revision cases needing augmentation before definitive reconstruction, or repair of periacetabular defects encountered during other hip procedures. Because the hip joint has separate body part values for the general joint and for the acetabular surface specifically, operative documentation should indicate precisely which component was augmented.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Synthetic Substitute
Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.
Coding & Documentation
Coders assign Supplement when documentation shows material was added to reinforce an existing body part rather than substitute for it, which requires confirming the native structure was not removed. Graft type, whether autograft, allograft, or synthetic, factors into the device value. A recurring mistake is coding a ligament reconstruction as Repair when a formal graft was placed, or conversely coding Supplement when the graft actually replaced a joint surface rather than reinforcing intact tissue.
