ICD-10-PCS Billable Code

0KUP0KZ

Supplement Hip Muscle, Left to No Qualifier with Nonautologous Tissue Substitute, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemK Muscles
OperationU Supplement
Body PartP Hip Muscle, Left
Approach0 Open
DeviceK Nonautologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

Procedure Overview

Supplement procedures in the muscle body system involve placing biological or synthetic material - such as surgical mesh, an acellular tissue matrix, or a patch graft - onto or into a muscle to reinforce it or restore some of its function, without replacing the muscle tissue itself. This approach is common in complex hernia repairs where the abdominal wall muscles are reinforced with mesh, in diaphragm reconstruction after a large defect, and in augmenting a weakened or partially torn muscle such as during certain rotator cuff procedures.

The goal is structural support rather than removal or replacement: the patient's own muscle stays in place, and the added material acts like an internal scaffold or patch that shares the load and encourages the surrounding tissue to heal with less risk of the defect reopening. This differs from procedures aimed at cutting out diseased tissue - Supplement is about strengthening what remains.

Anatomy & Axis Detail

Hip Muscle, Left

The left hip muscles, comprising the gluteal group along with the iliopsoas and deep external rotators, control hip extension, abduction, and rotational stability during gait. Supplement addresses situations where this muscle mass is present but structurally deficient, such as chronic gluteal tendinopathy with associated muscle thinning, prior surgical violation of the abductor mechanism during hip surgery, or reinforcement needed during revision arthroplasty, as opposed to suturing a fresh tear. Biologic mesh or acellular dermal matrix is commonly layered over the attenuated gluteus medius or minimus to restore mechanical integrity and reduce the risk of postoperative abductor insufficiency and limp. Because these muscles directly influence pelvic stability during single-leg stance, documentation should clarify that the procedure reinforced existing muscle rather than repairing or transferring it, particularly when performed alongside joint reconstruction.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Nonautologous Tissue Substitute

Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.

Coding & Documentation

Coders need explicit documentation that graft or mesh material was implanted to reinforce or augment the muscle, including the material type (synthetic mesh, xenograft, allograft, etc.), since this determines the device value in the code. A note that only describes suturing torn muscle edges together, with no mention of an added material, does not support Supplement. A frequent error is coding Supplement when the surgeon actually performed a straightforward Repair by suturing without any implanted material, or the reverse - missing a Supplement code when mesh reinforcement is mentioned only briefly within a longer operative narrative for a different primary procedure.

Commonly Confused With

RepairThis is most often confused with Repair, which restores a muscle to its normal structure using only sutures or the body's own tissue with no added material - the presence or absence of a graft or mesh is the deciding factor.
ReplacementIt also overlaps conceptually with Replacement, but Replacement substitutes the muscle tissue itself with a device or graft, whereas Supplement leaves the native muscle in place and adds reinforcement around or over it.