ICD-10-PCS Billable Code

04UT0KZ

Supplement Peroneal Artery, Right to No Qualifier with Nonautologous Tissue Substitute, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System4 Lower Arteries
OperationU Supplement
Body PartT Peroneal Artery, Right
Approach0 Open
DeviceK Nonautologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

Procedure Overview

Supplement procedures reinforce or augment an artery using additional biological or synthetic material without removing the native vessel segment, distinguishing them from Replacement, where the diseased tissue is excised. In the lower arteries this typically takes the form of patch angioplasty at an endarterectomy site, or endovascular placement of a covered stent graft that lines and reinforces a weakened or aneurysmal segment while the native artery remains in place.

Patients undergo this type of procedure when an artery has been narrowed by plaque removal and needs a widening patch to prevent restenosis, or when an aneurysm needs endoluminal reinforcement rather than open resection. It is common in both open vascular surgery and increasingly in endovascular aneurysm repair, where covered stent grafts are deployed to reinforce the arterial wall from within.

Anatomy & Axis Detail

Peroneal Artery, Right

The right peroneal artery arises from the tibioperoneal trunk and runs along the fibula deep within the posterior leg compartment, supplying muscles near the fibula and contributing collateral flow to the foot when the tibial arteries are diseased. Supplement of this vessel involves reinforcing an existing wall defect or repaired segment with patch material, often used when the peroneal artery serves as the primary remaining runoff vessel in severe tibial occlusive disease. Its deep intermuscular position makes surgical exposure more technically demanding than the anterior or posterior tibial arteries. Because this artery frequently becomes the target vessel of last resort for limb salvage, precise documentation of the patch material and repaired segment is important to distinguish Supplement from a full bypass graft procedure coded elsewhere.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Nonautologous Tissue Substitute

Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.

Coding & Documentation

Coders should confirm from the operative note that the native artery segment was left in place and that material, whether a bovine pericardial patch, synthetic patch, or covered endograft, was added to reinforce or widen it. The device value must reflect the specific material used, and the body part value should reflect the arterial segment being reinforced, which for endovascular aneurysm repair can span multiple named segments requiring multiple codes.

A frequent error is coding patch angioplasty performed after an endarterectomy as part of the Extirpation code for the plaque removal rather than as a separate Supplement code, when current guidance requires both steps to be captured. Another common mistake is applying Replacement device values to what is actually a reinforcing supplement.

Commonly Confused With

ReplacementReplacement is the primary point of confusion, since both use graft material, but the deciding factor is whether the native vessel was excised, which points to Replacement, or left intact and reinforced, which points to Supplement.
RestrictionEndovascular aneurysm repair in particular can be miscoded as Restriction if the coder focuses only on the narrowing effect of the graft rather than recognizing that new device material was permanently placed to reinforce the wall, which is the hallmark of Supplement.