ICD-10-PCS Billable Code

02UH07Z

Supplement Pulmonary Valve to No Qualifier with Autologous Tissue Substitute, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System2 Heart and Great Vessels
OperationU Supplement
Body PartH Pulmonary Valve
Approach0 Open
Device7 Autologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

Procedure Overview

Supplement procedures add biological or synthetic material to reinforce or enhance a portion of the heart or a great vessel without removing the existing structure. Common examples include patch repair of a septal defect, reinforcing a weakened area of the aortic wall, or placing material to strengthen a valve annulus during repair.

The goal is to shore up tissue that is present but insufficient on its own, whether because of a congenital hole, an aneurysm that has thinned the vessel wall, or a valve structure that needs extra support to function properly. Unlike a replacement, the body's own tissue stays in place and the added material works alongside it.

Patients typically encounter this term in the context of congenital defect closures, aortic aneurysm repairs, and valve repair techniques that use patches, rings, or other reinforcing materials rather than swapping out the whole valve or vessel.

Anatomy & Axis Detail

Pulmonary Valve

The pulmonary valve, a thin trileaflet structure between the right ventricle and pulmonary trunk, operates under lower pressure than the systemic valves but can still be affected by congenital malformation, carcinoid involvement, or damage from prior right ventricular outflow tract surgery. Supplementing this valve typically involves patching a leaflet or the surrounding outflow tract with pericardial or synthetic material to relieve stenosis or correct regurgitation while preserving native valve tissue, a strategy especially relevant in congenital heart repairs such as tetralogy of Fallot corrections where transannular patching augments a hypoplastic outflow tract. Because the pulmonary valve's leaflets are thinner and more delicate than the aortic valve's, surgeons must balance adequate augmentation against the risk of creating a floppy, incompetent leaflet, and operative reports should specify whether the patch spans the valve alone or extends into the pulmonary trunk.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Autologous Tissue Substitute

Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.

Coding & Documentation

Coders assign Supplement when the note documents that material, biological or synthetic, was added to reinforce or augment existing anatomy, such as closing a septal defect with a patch or buttressing a vessel wall. The documentation should identify the material used and confirm that native tissue was not removed and replaced, only strengthened.

The most frequent error is confusing patch closure of a defect, which is Supplement, with actual replacement of a structure, which requires taking out the original part. Another common mistake is missing that some valve repairs combine Supplement for annuloplasty ring placement with Repair for other steps done in the same operative session, each of which needs its own code.

Commonly Confused With

ReplacementSupplement is closely confused with Replacement, where the distinction is whether native tissue is removed, as in Replacement, or left in place and reinforced, as in Supplement.
RepairIt also overlaps with Repair, the default root operation used when no other term fits; if a patch is placed specifically to reinforce or close a defect using added material, Supplement takes priority over Repair.
RestrictionCoders should also distinguish Supplement from Restriction, since a patch that narrows an oversized structure to normal caliber may actually reflect a Restriction if that narrowing is the primary intent rather than reinforcement.