ICD-10-PCS Billable Code

0PU63KZ

Supplement Scapula, Left to No Qualifier with Nonautologous Tissue Substitute, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemP Upper Bones
OperationU Supplement
Body Part6 Scapula, Left
Approach3 Percutaneous
DeviceK Nonautologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

Procedure Overview

Supplement procedures add biological or synthetic material to reinforce or augment a bone of the skull, face, thorax, or upper limb that remains anatomically in place, rather than replacing or repairing damaged tissue. Common examples include bone grafting to reinforce a weakened area of the skull, or augmenting a thin area of the sternum or scapula with mesh or cement to add structural strength.

This approach is chosen when the native bone is largely intact and functional but needs extra support, often to prevent future fracture, to build up bone stock before another procedure, or to strengthen a surgical repair site.

Anatomy & Axis Detail

Scapula, Left

The left scapula sits over the posterior rib cage and provides the mobile base from which the rotator cuff and periscapular muscles act on the shoulder. Supplement here typically follows oncologic resection, severe fracture nonunion, or reconstructive surgery where bone graft or a structural implant is used to rebuild a deficient portion of the bone and preserve the muscle attachment sites that make shoulder motion possible. Given the scapula's thin, curved architecture, the graft must be shaped to restore both strength and the gliding surface against the chest wall. Records should note left-sided laterality and the graft material used, as scapular reconstructions are typically tailored to the specific defect rather than performed as a routine procedure.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Nonautologous Tissue Substitute

Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.

Coding & Documentation

Coders should confirm the operative note describes material being added to reinforce a structure that stays in place, not material substituting for a removed part. The device or graft type documented determines the correct device value - autograft, allograft, synthetic substitute, or nonautologous tissue - so vague documentation of "bone graft" without a source can complicate accurate coding. A common mistake is coding supplement when the surgeon actually performed a replacement, particularly in cranioplasty cases where it's unclear whether native bone was removed first. Another frequent error is missing a supplement code entirely when a graft was placed during a repair or reposition procedure, since it may require a separate code rather than being bundled in.

Commonly Confused With

ReplacementReplacement is the closest match and the two are distinguished by whether the original bone was removed - supplement reinforces bone left in place, while replacement requires a body part to be taken out before the substitute goes in.
RepairRepair can also overlap since both may involve grafting, but repair is coded when the graft is restoring a structural defect rather than adding reinforcing bulk to an already intact structure.