0VUH47Z
Supplement Spermatic Cords, Bilateral to No Qualifier with Autologous Tissue Substitute, Percutaneous Endoscopic Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | V Male Reproductive System |
| Operation | U Supplement |
| Body Part | H Spermatic Cords, Bilateral |
| Approach | 4 Percutaneous Endoscopic |
| Device | 7 Autologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
Procedure Overview
Supplement procedures put in biological or synthetic material to reinforce or augment a body part that is still present, rather than replacing or repairing it outright. In the male reproductive system this includes using graft material - synthetic mesh or donor tissue - to reinforce the tunica albuginea during correction of Peyronie's disease, or grafting to support tissue during complex penile or scrotal reconstruction. The native structure stays in place; the graft adds strength or bulk it currently lacks.
These procedures are often part of reconstructive surgery for congenital conditions, traumatic injury, or acquired scarring conditions like Peyronie's disease, where the goal is to correct curvature or reinforce a weakened area while preserving the patient's own tissue.
Anatomy & Axis Detail
Spermatic Cords, Bilateral
This bilateral value applies when both spermatic cords receive supplementing material, such as mesh reinforcement, during the same operative episode, most often in the setting of bilateral inguinal hernia repair where cord structures on each side are reinforced concurrently. Because the spermatic cords are paired but anatomically distinct structures on either side of the midline, this combined code is reserved for cases where equivalent supplementing procedures occur on both cords in one surgical encounter, rather than being used loosely whenever both groins are addressed. Surgeons may use different graft materials or techniques on each side, in which case separate laterality-specific codes would be more accurate than the bilateral value. Careful review of the operative report is needed to confirm true bilateral, same-session supplementation of the cord structures themselves.
Approach: Percutaneous Endoscopic
Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.
Device: Autologous Tissue Substitute
Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.
Coding & Documentation
Correct coding depends on the operative note specifying that graft or reinforcing material was added to an existing structure, along with the type of material used - autograft, allograft, or synthetic - since this drives the device or qualifier value. A common mistake is coding Supplement when the documentation actually describes a Repair alone with simple suture closure and no reinforcing material, or conversely missing the Supplement code when a Peyronie's plaque incision was reinforced with a graft that should be captured separately from the underlying procedure.
