ICD-10-PCS Billable Code

C722YZZ

Tomographic (Tomo) Nuclear Medicine Imaging Spleen to None with None, Other Radionuclide Approach

Procedural Specifications

Clinical Axis Detail Definition
SectionC Nuclear Medicine
Body System7 Lymphatic and Hematologic System
Operation2 Tomographic (Tomo) Nuclear Medicine Imaging
Body Part2 Spleen
ApproachY Other Radionuclide
DeviceZ None
QualifierZ None

Operation Definition

Introduction of radioactive materials into the body for three dimensional display of images developed from the capture of radioactive emissions

Procedure Overview

Tomographic nuclear medicine imaging of the lymphatic and hematologic system produces three-dimensional pictures built from radioactive emissions captured as a detector rotates around the patient, offering more spatial detail than a flat, single-plane scan. Common applications include imaging the spleen to evaluate its size, function, or the presence of accessory spleen tissue, and bone marrow scans that assess how well marrow is producing blood cells across the skeleton.

These studies are typically ordered when a flat image would not give enough detail to answer the clinical question, such as when a physician needs to see the exact three-dimensional distribution of functioning marrow, or precisely localize splenic tissue before a planned surgery. The added detail comes from the same rotational data-collection principle used in other tomographic nuclear medicine studies, just applied to lymphatic and blood-forming tissue rather than another organ system.

Anatomy & Axis Detail

Spleen

Tomographic imaging of the spleen, typically performed as SPECT following administration of a technetium-99m sulfur colloid or heat-damaged autologous red blood cells, exploits the organ's dense reticuloendothelial and reticulocyte-clearing activity to generate cross-sectional maps of splenic tissue. This approach is used to confirm splenic size, position, and functional parenchyma when anatomic imaging is equivocal, to detect accessory spleens or splenosis after splenectomy, and to distinguish an upper abdominal mass from splenic tissue. Because the spleen sits adjacent to the left kidney, stomach, and colon, three-dimensional reconstruction is particularly valuable for separating overlapping activity that a single planar view would obscure. Reduced or absent uptake can indicate infarction, atrophy, or functional asplenia, while focal photopenic defects raise concern for cysts, abscess, or infiltrative disease within the splenic parenchyma.

Radionuclide: Other Radionuclide

Other Radionuclide is used when a nuclear medicine study employs a radioactive tracer that does not correspond to one of the specifically named isotope values in this axis, such as an uncommon or newer radiopharmaceutical. It functions as a catch-all so the procedure can still be coded precisely by section and root operation even when the exact tracer lacks its own dedicated code value.

Coding & Documentation

Documentation needs to establish that the images were reconstructed from a rotational, three-dimensional acquisition rather than a series of flat views, since this is the feature that separates this root operation from planar imaging of the same body system. The specific organ or tissue studied, such as spleen versus bone marrow, should be clearly identified because it drives body part selection. A recurring error is coding a tomographic marrow or spleen study as a general "blood" study without pinning down the actual anatomic target documented in the radiology report.

Commonly Confused With

The closest source of confusion is Planar Nuclear Medicine Imaging of the same body system; both use similar tracers and target the same organs, but the tomographic version is reserved for studies that specifically reconstruct a three-dimensional volume rather than capturing single flat views. It can also be confused with PET imaging of other body systems when FDG is used for lymphoma staging, but lymphoma PET studies are typically coded under a whole-body or different body-system category rather than this lymphatic and hematologic tomographic family, depending on what the report actually documents.

Procedural Guidance & FAQs

Coding Accuracy

Is C722YZZ a billable procedure?

Yes, C722YZZ is a complete, 7-character procedural specification that is acceptable for hospital claim reimbursement.

Technical Axis

What approach is used for C722YZZ?

This procedure utilizes the Other Radionuclide approach, mapping to the 5th character in the PCS axis.

Metadata Tags

radionuclide spleen nuclear tomographic imaging medicine