ICD-10-CM Billable Code

T85.123

Displacement of implanted electronic neurostimulator, generator

Clinical Classification Guidelines

Inclusion Terms

  • Displacement of implanted electronic neurostimulator generator, brain, peripheral, gastric, spinal
  • Displacement of implanted electronic sacral neurostimulator, pulse generator or receiver

Medical Intelligence & Overview

Displacement of an implanted electronic neurostimulator generator occurs when the device's pulse generator or receiver shifts from its original position after implantation. Neurostimulators are medical devices used to deliver electrical impulses to specific parts of the body to manage pain, neurological disorders, or other medical conditions. Displacement can affect the device's function and may require medical attention to reposition or replace the implant. This condition can involve neurostimulators placed in the brain, spine, peripheral nerves, stomach, or sacral region.

Causes & Symptoms

Clinical Causes: Accidental trauma or injury causing movement of the device Insufficient securing of the neurostimulator during surgery Wear and tear over time weakening device placement Physical activities or movements that exert pressure on the implant site Infections leading to loosening of the device Natural tissue changes or scarring after surgery

Key Symptoms: Sudden loss or reduction of the device’s effects Pain or discomfort around the implantation site Visible or palpable movement of the device Swelling, redness, or signs of infection at the implant site Skin changes or tenderness over the implanted area Numbness or altered sensations near the implant Unexplained muscle weakness or spasms

Diagnostic & Treatment

Diagnosis Path: Diagnosis involves clinical examination and imaging studies such as X-rays, ultrasound, or MRI to assess the position of the neurostimulator. The healthcare provider may also review the device’s function through specialized testing to determine if displacement has affected its performance. Patient history regarding recent trauma, activities, or symptoms is critical in diagnosing displacement.

Treatment Protocols: Management depends on the severity and symptoms of displacement. Treatment options include: - Observation: Mild cases without symptoms may be monitored over time. - Repositioning: Surgical intervention to move the device back to its proper location. - Replacement: In cases where the device cannot be securely repositioned, replacement of the neurostimulator may be necessary. - Addressing underlying causes: Treating infections or stabilizing tissue to prevent further displacement. Postoperative care and follow-up are essential to ensure proper healing and function of the neurostimulator after repositioning or replacement.

Reimbursement claims with a date of service on or after October 1, 2015 require the use of ICD-10-CM codes.

Clinical Advice & FAQs

Billing Guidance

Is T85.123 a billable ICD-10 code?
Yes, T85.123 is a specific, billable code that can be used to indicate a diagnosis for reimbursement purposes.

Documentation

How do I report T85.123?
Clinical documentation must specify the nature of Displacement of implanted electronic neurostimulator, generator and any associated comorbidities for accurate reporting.

Cite this Clinical Reference