067N0DZ
Dilation Femoral Vein, Left to No Qualifier with Intraluminal Device, Open Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | 6 Lower Veins |
| Operation | 7 Dilation |
| Body Part | N Femoral Vein, Left |
| Approach | 0 Open |
| Device | D Intraluminal Device |
| Qualifier | Z No Qualifier |
Operation Definition
Expanding an orifice or the lumen of a tubular body part
Procedure Overview
Dilation procedures widen a lower vein that has become narrowed, most commonly the iliac vein or another deep vein in the pelvis or leg affected by scarring from a prior blood clot or external compression. Using a balloon catheter threaded through the vessel, sometimes followed by placement of a stent to hold the vein open, physicians restore normal blood flow through a segment that had been constricting circulation.
This approach is frequently used to treat May-Thurner syndrome, where the right iliac artery compresses the left iliac vein, or to open veins scarred by post-thrombotic syndrome following deep vein thrombosis. Patients typically experience leg swelling, heaviness, or skin discoloration that improves once normal venous drainage is restored.
Anatomy & Axis Detail
Femoral Vein, Left
The left femoral vein carries deep venous drainage from the left leg toward the pelvis and is a well-recognized site for chronic obstruction following deep vein thrombosis, particularly when combined with iliac compression from May-Thurner physiology. Balloon dilation of this vessel addresses residual scarring or synechiae that narrow the lumen after thrombus organization, aiming to restore unobstructed outflow and reduce post-thrombotic symptoms. The left femoral vein's relationship to the profunda femoris confluence means operators must take care that dilation does not compromise flow at this junction. Because left-sided iliofemoral disease often extends across multiple contiguous segments, this vein is frequently treated in the same session as the adjacent iliac vein, and each treated segment should be coded separately to reflect the full extent of the intervention.
Approach: Open
Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.
Device: Intraluminal Device
Intraluminal Device denotes a single device, such as a stent or occlusion device, positioned within the lumen of a tubular body part like a vessel, duct, or airway to maintain patency or occlude flow. It carries no drug coating or radioactivity, distinguishing it from the drug-eluting, radioactive, and bioactive intraluminal device values, and from Extraluminal Device, which sits outside rather than inside the lumen.
Coding & Documentation
Documentation should clearly state that a balloon or similar device widened the vein's lumen, and if a stent was left behind to maintain the opening, that becomes the device value on the code rather than being left as a 'no device' case. The specific vein segment treated, such as the common iliac vein versus the external iliac vein, must be identified precisely since these are distinct body part values.
A recurring error is coding Dilation without capturing a stent that was actually placed, defaulting to a no-device value when the operative report clearly documents a permanent intraluminal device. Coders also sometimes conflate angioplasty of an adjacent artery performed in the same session with the venous dilation, which requires a separate code from a different body system.
