0LC14ZZ
Extirpation Shoulder Tendon, Right to No Qualifier with No Device, Percutaneous Endoscopic Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | L Tendons |
| Operation | C Extirpation |
| Body Part | 1 Shoulder Tendon, Right |
| Approach | 4 Percutaneous Endoscopic |
| Device | Z No Device |
| Qualifier | Z No Qualifier |
Operation Definition
Taking or cutting out solid matter from a body part
Procedure Overview
Tendon extirpation procedures take or cut out solid matter that has formed within or around a tendon but is not itself normal tendon tissue, such as a foreign body, a blood clot, or a calcified deposit that has hardened within the tendon. This differs from removing part of the tendon structure itself, since the target here is abnormal material lodged in or against the tendon rather than the tendon's own tissue.
Common scenarios include removing a splinter or suture fragment that migrated into a tendon sheath, evacuating an organized hematoma that has not resolved on its own, or extracting calcific deposits associated with calcific tendinitis that have become symptomatic. The surgeon may need to make an incision to access and extract the material, and the procedure is considered complete once the solid matter is out, without any tendon tissue itself being excised.
Anatomy & Axis Detail
Shoulder Tendon, Right
The right shoulder tendon group includes the rotator cuff tendons, biceps tendon, and other structures crossing the glenohumeral joint that enable arm elevation and rotation. Extirpation here targets solid material abnormally present within or around a tendon, such as a foreign body from penetrating trauma, a loose calcific deposit from calcific tendinitis, or debris from a prior surgical procedure. Unlike excision, the goal is not to remove tendon tissue itself but to clear the obstructing or foreign material while preserving the tendon's structural integrity. The rotator cuff tendons, being thin and functionally critical for shoulder stability, require meticulous technique to avoid iatrogenic injury during extraction, particularly given their proximity to the subacromial space and long head of the biceps tendon.
Approach: Percutaneous Endoscopic
Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.
Coding & Documentation
Extirpation is coded when documentation describes removing solid matter, abnormal by presence or amount, from within or around the tendon, distinct from removing a piece of the tendon itself. The note should specify what was extracted, such as a calcific deposit, foreign body, or organized clot, and the tendon or region involved.
A frequent coding error is applying Extirpation to routine debridement of degenerated tendon tissue, which actually belongs under Excision because that tissue is part of the tendon rather than foreign or abnormal material lodged within it. Coders also sometimes miss that if the extracted material is accompanied by simple fluid drainage in the same operative field, both actions may need separate codes depending on what exactly was documented as removed.