0UH98HZ
Insertion Uterus to No Qualifier with Contraceptive Device, Via Natural or Artificial Opening Endoscopic Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | U Female Reproductive System |
| Operation | H Insertion |
| Body Part | 9 Uterus |
| Approach | 8 Via Natural or Artificial Opening Endoscopic |
| Device | H Contraceptive Device |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
Procedure Overview
Insertion procedures place a nonbiological device into the female reproductive system to monitor, assist, or support a physiological function without replacing any body part - the intrauterine device is the most familiar example, along with certain drainage devices, tandem or applicator placements for radiation therapy, or monitoring devices placed temporarily during labor. The device itself performs a function or delivers therapy, but it does not take over the role of an organ the way an implant or prosthesis would.
Patients receive these procedures for contraception, targeted hormone or medication delivery, radiation therapy setup for gynecologic cancers, or intrapartum monitoring. Because the device is meant to be positioned within an existing body part rather than replacing tissue, Insertion is coded separately from procedures that reconstruct or replace anatomy.
Some of these devices are left in place long-term, like a hormonal IUD intended to remain for years, while others such as a radiation applicator are placed temporarily for a single treatment session and then removed in a distinct subsequent procedure.
Anatomy & Axis Detail
Uterus
PLACEHOLDER
Approach: Via Natural or Artificial Opening Endoscopic
Via Natural or Artificial Opening Endoscopic describes instrumentation introduced through a natural orifice or a surgically created opening while using an endoscope for visualization, as in a routine colonoscopy performed through the anus. It differs from the plain Via Natural or Artificial Opening value by the added scope, and from Percutaneous Endoscopic by using an existing passage rather than a new skin puncture.
Device: Contraceptive Device
A contraceptive device is an implant placed to prevent pregnancy, such as an intrauterine device or a subdermal hormonal rod, and is coded to reflect the device left in place after the procedure. It is a distinct device category from other reproductive system implants and is not used interchangeably with diagnostic or therapeutic devices placed for other indications.
Coding & Documentation
Coding requires documentation identifying the specific device placed - IUD, radiation applicator, monitoring catheter - and the body part into which it was inserted, since the device type determines the code's device value. Notes confirming placement location, such as intrauterine positioning confirmed by ultrasound, support accurate body part assignment, and coders should check for any imaging verification documented as part of the procedure.
A frequent error is coding routine IUD insertion without capturing that a separate removal of a prior device occurred in the same encounter, which requires its own code. Coders also sometimes misclassify placement of a device meant to replace tissue function, such as certain slings or mesh, as Insertion when the correct root operation is actually Replacement or Supplement depending on what the device does.
