0QPMX5Z
Removal Tarsal, Left to No Qualifier with External Fixation Device, External Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | Q Lower Bones |
| Operation | P Removal |
| Body Part | M Tarsal, Left |
| Approach | X External |
| Device | 5 External Fixation Device |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
Removal procedures take out a device that was previously placed in or on a lower bone - hardware such as plates, screws, rods, pins, external fixator components, or spacers used in the pelvis, femur, tibia, fibula, patella, or foot bones. These devices are typically inserted to stabilize a fracture, hold a bone graft, or support a joint during healing, and removal happens once that purpose has been served or if the device is causing a problem.
Reasons for removal vary widely. Hardware may simply be scheduled for extraction after a fracture has healed, especially in children whose growing bones can be irritated by permanent implants. In other cases the device is removed because it has become infected, has loosened, is causing pain from irritating overlying soft tissue, or is interfering with a later procedure such as a joint replacement.
Anatomy & Axis Detail
Tarsal, Left
The left tarsal bones make up the hindfoot and midfoot, and Removal procedures here address hardware left from calcaneal fracture fixation, subtalar or midfoot arthrodesis, or reconstructive flatfoot surgery. Fixation across these small, irregularly shaped bones often uses screws or plates positioned close to weight-bearing surfaces of the sole, so retained hardware frequently becomes symptomatic with prolonged standing or tight footwear even after solid bony union. Screws that cross a fusion site are sometimes deliberately left permanently, while those causing joint impingement or soft-tissue irritation are removed electively. Given the close proximity of multiple tarsal bones, precise identification of the specific bone from which the device is extracted matters for accurate documentation, since the tarsal group covers several anatomically distinct structures.
Approach: External
External approach applies to procedures performed directly on the skin or mucous membrane, or on an accessible body surface, without any instrumentation passing through a puncture or orifice. It covers things like manual reduction of a fracture or excision of a skin lesion. It differs from Via Natural or Artificial Opening in that no internal passage is entered at all, only the exposed surface.
Device: External Fixation Device
This is the general external fixation device value, used when pins or wires anchored in bone are connected to a stabilizing frame outside the body to hold a fracture or joint in position, without specifying a more particular frame configuration. It contrasts with the more specific External Fixation Device subtypes - Monoplanar, Ring, Hybrid, and Limb Lengthening - which describe the frame's geometry or added lengthening function.
Coding & Documentation
Coders assign Removal when documentation confirms a device is being taken out and not replaced with another device during the same operative episode - if a new device goes in at the same site, the procedure is Change or a combination of Removal and another root operation such as Insertion, not Removal alone. The device type and the specific bone it was removed from both need to be identifiable from the operative note. A common error is coding Removal for hardware that is only being adjusted or repositioned rather than fully extracted, or overlooking that the removal of a device is bundled into a broader procedure when substantial additional work, like bone repair, is performed at the same site.
