ICD-10-PCS Billable Code

06R147Z

Replacement Splenic Vein to No Qualifier with Autologous Tissue Substitute, Percutaneous Endoscopic Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System6 Lower Veins
OperationR Replacement
Body Part1 Splenic Vein
Approach4 Percutaneous Endoscopic
Device7 Autologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part

Procedure Overview

This family covers procedures where a diseased or damaged segment of a lower-body vein - in the leg, pelvis, or abdomen - is physically removed and replaced with another material that takes over its job of carrying blood back toward the heart. The replacement material can be a graft harvested from the patient's own body, tissue from a donor or animal source that has been processed for implantation, or a synthetic conduit made from materials like expanded PTFE. It is most often considered when a vein segment is too scarred, obstructed, or aneurysmal to repair in place.

Surgeons turn to this approach in situations such as reconstructing a badly damaged femoral or iliac vein after trauma, cancer resection that required removing a vein along with a tumor, or chronic venous disease that has destroyed a segment beyond salvage. The goal is to restore a functioning channel for venous return rather than simply tying off the vessel, which can be important for preventing long-term swelling and pressure buildup in the limb.

Because deep veins carry a large volume of blood at low pressure, these reconstructions are technically demanding and are typically reserved for cases where the alternative - vein ligation or leaving the segment untreated - would cause significant disability.

Anatomy & Axis Detail

Splenic Vein

The splenic vein runs along the posterior pancreas and drains the spleen and portions of the stomach and pancreas into the portal system, making it vulnerable to compression or invasion by pancreatic tumors, pancreatitis-related thrombosis, or splenic pathology. Replacement of a diseased segment with a graft is a technically demanding step within larger pancreatic or splenic resections, undertaken when the vessel cannot simply be repaired or ligated without compromising portal inflow and risking left-sided portal hypertension. Its close anatomic relationship to the pancreatic tail and portal confluence means replacement is rarely an isolated operation, and documentation should reflect its role within the broader procedure, such as pancreatectomy with vascular reconstruction.

Approach: Percutaneous Endoscopic

Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.

Device: Autologous Tissue Substitute

Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.

Coding & Documentation

A code from this family requires documentation that a vein segment was excised or entirely taken out of the body and replaced with graft material, not simply patched, bypassed, or reinforced on its outer surface. The operative note should specify the exact vein involved (e.g., common femoral vein versus external iliac vein) and the type of material used, since device value selection depends on whether the graft is autologous tissue, nonautologous tissue, or synthetic.

The most common assignment error is confusing Replacement with Supplement or Bypass. If the native vein is left in place and the graft material is only added to reinforce or widen it, Supplement applies instead. If the graft creates an alternate route around a blocked segment while the diseased vein remains, that is a Bypass procedure, not Replacement. Coders should also confirm the qualifier for autologous versus nonautologous tissue, which is frequently omitted or guessed rather than confirmed from the documentation.

Commonly Confused With

BypassBypass procedures on lower veins are the most frequent point of confusion, since both involve grafts and both are used for obstructed venous segments; the distinction is whether the diseased vein is removed (Replacement) or bypassed while remaining in the body (Bypass).
SupplementSupplement is also easily mistaken for Replacement when a patch or cuff is added to a vein wall rather than a full segment being excised and swapped out - Supplement always leaves the original body part fundamentally in place.
RepairRepair, used for less extensive suture or graft closures without device placement intent, is a separate and much more limited category.