0SWE4JZ
Revision Hip Joint, Acetabular Surface, Left to No Qualifier with Synthetic Substitute, Percutaneous Endoscopic Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | S Lower Joints |
| Operation | W Revision |
| Body Part | E Hip Joint, Acetabular Surface, Left |
| Approach | 4 Percutaneous Endoscopic |
| Device | J Synthetic Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Procedure Overview
Revision procedures correct a malfunctioning device already implanted in a lower joint, or reposition a device that has shifted out of place, without necessarily removing and replacing the whole implant. Examples include tightening a loosened hip component, adjusting a worn knee liner, or repositioning a dislocated joint implant back into alignment. The reason for surgery is a problem with hardware from an earlier operation rather than new injury to native tissue.
These procedures are often needed years after an initial joint replacement, as components can loosen, wear, or shift with normal use. Surgeons aim to fix the specific mechanical problem while preserving as much of the existing implant and surrounding bone as possible, since more extensive revisions carry greater surgical risk and longer recovery.
Anatomy & Axis Detail
Hip Joint, Acetabular Surface, Left
The acetabular surface of the left hip joint is the pelvic socket component that receives the femoral head, typically resurfaced with a prosthetic shell and liner during hip arthroplasty performed for arthritis, dysplasia, or fracture. As with its right-sided counterpart, this body part is coded separately from the hip joint overall, and revision applies specifically when the acetabular component has loosened, worn, or shifted position and requires correction while remaining in place rather than being replaced with a new implant. Accurate coding depends on the operative note clearly identifying that the acetabular side, rather than the femoral side, of the left hip prosthesis is the structure being revised, along with confirming laterality to the left.
Approach: Percutaneous Endoscopic
Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.
Device: Synthetic Substitute
Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.
Coding & Documentation
Documentation needs to identify that an existing device was the target of correction, whether through repositioning, adjustment, or partial component exchange, and that the fix did not amount to a full swap of the entire prosthesis. Notes describing loosening, malposition, or component wear typically support Revision. A common error arises when a full component exchange occurs during a documented revision surgery; if the entire device is replaced, the correct root operation is Replacement, even though the surgeon may call it revision arthroplasty.
