ICD-10-CM Billable Code

M27.61

Osseointegration failure of dental implant

Clinical Classification Guidelines

Inclusion Terms

  • Hemorrhagic complications of dental implant placement
  • Iatrogenic osseointegration failure of dental implant
  • Osseointegration failure of dental implant due to complications of systemic disease
  • Osseointegration failure of dental implant due to poor bone quality
  • Pre-integration failure of dental implant NOS
  • Pre-osseointegration failure of dental implant

Medical Intelligence & Overview

Osseointegration is the process by which a dental implant fuses securely with the jawbone, providing stability for dental restorations. When this process fails, the implant may become loose or fail to integrate altogether, leading to the diagnosis known as osseointegration failure (ICD-10 code M27.61). This condition can happen due to various factors, including complications during or after the placement of the implant. Recognizing the causes and symptoms of osseointegration failure is important for proper management and treatment planning.

Causes & Symptoms

Clinical Causes: Hemorrhagic complications during dental implant placement, leading to bleeding and possible interference with bone healing. Iatrogenic causes, where surgical errors or technical issues during the procedure impair integration. Systemic diseases such as uncontrolled diabetes, osteoporosis, or other conditions that affect bone health and healing. Poor bone quality, including insufficient or degraded bone that cannot support proper implant integration. Pre-integration or pre-osseointegration failure, occurring when the process of bone healing and attachment does not progress as expected, before the implant fully integrates. Infections around the implant site, which can hinder osseointegration. Smoking, which reduces blood flow and impairs healing processes. Use of certain medications, such as bisphosphonates, that may affect bone metabolism. Poor oral hygiene, leading to peri-implantitis and complications in healing.

Key Symptoms: Looseness of the dental implant, often noticed by the patient or dentist. Discomfort or pain around the implant site, especially when biting or applying pressure. Swelling, redness, or signs of infection around the implant area. Bone loss observable through dental X-rays. Persistent or increasing gum inflammation near the implant. In some cases, a foul taste or odor may develop if infection is present. Failure of the implant to function or remain securely attached over time.

Diagnostic & Treatment

Diagnosis Path: Diagnosis of osseointegration failure involves a thorough clinical examination and imaging studies. Dentists assess the stability of the implant, look for signs of inflammation or infection, and review radiographs to observe bone levels surrounding the implant. If the implant appears loose or there are signs of bone loss, additional diagnostic procedures may be performed to determine the underlying cause and extent of failure.

Treatment Protocols: Treatment options depend on the severity and cause of the failure. Possible approaches include: - Removing the failed implant and allowing the site to heal before considering re-implantation. - Addressing underlying systemic health issues or risk factors, such as controlling blood sugar levels or ceasing smoking. - Managing infections with appropriate antibiotics. - Enhancing bone quality through regenerative procedures like grafting if necessary. - Implementing improved surgical techniques or technology during re-implantation. - Ensuring optimal oral hygiene and maintenance to prevent recurrence. A dental professional will guide the patient through the best course of action based on individual circumstances.

Reimbursement claims with a date of service on or after October 1, 2015 require the use of ICD-10-CM codes.

Clinical Advice & FAQs

Billing Guidance

Is M27.61 a billable ICD-10 code?
Yes, M27.61 is a specific, billable code that can be used to indicate a diagnosis for reimbursement purposes.

Documentation

How do I report M27.61?
Clinical documentation must specify the nature of Osseointegration failure of dental implant and any associated comorbidities for accurate reporting.

Cite this Clinical Reference

Clinical Meta Tags

failure dental osseointegration implant